Impact
List of deliverables
D1. Recommendations on which reference radiation qualities should be included into IEC 61267 and evidence submitted to IEC SC62C WG 3 and IAEA CRP E24024 officers.
D2. Open access spectrum catalogue including spectra for reference radiation qualities currently described in IEC 61267 and the recommended new reference radiation qualities (RRQs) and evidence submitted to IEC SC62C WG 3.
D3. Paper on the performance of at least 8 commercially available X‑ray dosimeter types in at least 3 NMIs/DIs covering different influence quantities, especially the defined clinically representative radiation qualities, enabling estimation of uncertainties related to air kerma measurements with different dosimeters.
D4. Recommendations on the specific requirements such as compliance tests and rated ranges for reference- and field-class dosimeters enabling traceable clinical measurements with the targeted uncertainty 7 % (k=2) and to be updated in future revisions of IEC 61674 and evidence submitted to IEC SC62C WG 3 and IAEA CRP E24024 officers.
D5. Report on the performance of at least 5 commercially available X‑ray multimeters in laboratory and clinical conditions tested in at least 3 NMIs/DIs and 3 clinics enabling estimation of uncertainties related to measurements of different quantities. This report will include recommendations for an update of IEC 61676 and inclusion of other relevant QA parameters in new or existing standards and evidence submitted to TC 62 SC62C WG3, IAEA CRP E24024 officers.
D6. Calibration and measurement procedures of X-ray multimeters at laboratories and clinical conditions covering relevant clinical parameters such as air kerma, PPV and half-value layer and target uncertainties submitted to IAEA CRP E24024 officers providing inputs for the update of the TRS-457.
D7. Draft B comparison report for supplementary comparison for air kerma calibrations in X-ray imaging reference radiation qualities with specified uncertainties submitted to EURAMET TC IR.
D8. Draft B comparison report for supplementary comparison for X‑ray tube voltage calibrations in X‑ray imaging reference radiation qualities with specified uncertainties submitted to EURAMET TC IR.
D9. Evidence of contributions to or influence on new or improved international guides, recommendations and standards with a specific focus on the following guides and committees: IAEA TRS-457 and IEC SC62C WG 3.
Examples of early uptake of project outputs by end-users.
Updated dissemination, communication and exploitation plan.
D10. Delivery of all technical and financial reporting documents as required by EURAMET.